CDS IDLE CHECK
CDS IDLE CHECK
NOTE: CDS has created 4 tstols that will allow the FOT to run scripts for common CDS
activities. The 4 tstols are for CDS submode preparation to make sure CDS is properly prepped for the sumbode change, to safe CDS incase of a proton event, to close CDS doors, and to open CDS doors.
TSTOL - CDS_SUBMODE_PREP
- Purpose: This procedure will open/ensure CDS is prepared for submode transition.
- When: Prior to any submode transition, and Only upon CDS or SOC request.
- If CKCMODE (does not equal) "90" then abort.
TSTOL - CDS_PROTON_SAFE
- Purpose: This procedure is to be run if proton levels GEOS-8 energy threshold "50 MEV" (blue line)
reaches or exceeds level 10^2, CDS will beed to be safed.
- When: Only upon CDS request.
- Disable CDS deferred commands stored
- Abort current running study
- Clear deferred commands stored
- Disable NIS high voltage
- Disable GIS high voltage
TSTOL - CDS_SHUTDOORS
- Purpose: This procedure will close CDS doors.
- When: Only upon CDS request.
- Turn on power to door
- Shut VDS door
- Shut GIS door
- Turn off power to door
TSOTL - CDS_OPENDOORS
- Purpose: This procedure will open CDS doors.
- When: Only upon CDS request.
- Turn on power to door
- Open VDS door
- Open GIS door
- Turn off power to door
NOTE: The notes below are old
How to check if CDS is idle so we can do a submode change:
Location: /u/ecs/soc/info/cds_idle_info.html