Study 000302: ACRONYM: GDZ_LT_JET_60x160 OBJECTIVE: Monitor with a 12m cadence an area of 60x120, to measure flows and electron densities in X-ray jets located inside coronal holes. TARGET : Coronal hole region EXPOSURE TIME : 20s RASTER : Scanning SLIT : 2" STEP_SIZE : 2" FOV : 60"x160" SPECTRAL WIND.: 16 DATA COMP. : JPEG90 RASTER DURATON: 11m 30s DATA volume : 9.66 Mbits DATA volume/H : 48 Mbits/h LINES : He II, O V, Si VII, SiX, Ca XVII Fe VIII X,XI,XII,XIII,XIV,XV,XVI,XVII, XXIII POINTING: a bright point inside a coronal hole region. INSTRUCTION TO PLANNERS: Ensure that the EIS FOV is aligned with SOT FOV Study must be repeated following the region for at least 6 hours. It is important to coordinate with TRACE planners so TRACE 195 A band is observed during the same period of observation. WARNING: The 20s exposure will produce low signal in most lines in the coronal hole, so this study is not well suited for coronal hole studies.