Study 000309: ACRONYM: GDZ_LT_PLUME_10x180 Monitor with a 3m cadence and low telemetry an area of 10'x184", to measure flows and electron densities in a plume located inside coronal holes. TARGET : Coronal hole region EXPOSURE TIME : 25s RASTER : Scanning SLIT : 2" STEP_SIZE : 2" FOV : 10"x184" SPECTRAL WIND.: 15 DATA COMP. : JPEG90 RASTER DURATON: 2m 21s DATA volume : 1.49 Mbits LINES : He II, O V, Si VII, SiX, Ca XVII Fe VIII X,XI,XII,XIV,XVI, XXIII POINTING: the base of a plume inside a coronal hole region. INSTRUCTION TO PLANNERS: 1 - Shift the EIS CCD window (Y-direction) if needed, so as to have SOT and EIS to observe the same on-disc region. 2 - The study (duration 2m 44s) must be repeated 10 times following the region (27m - 14.9 Mbits). Then the sequence should be repeated 5 times changing everytime the pointing by 10" (total of 2h 16m, 75 MBits) in order to scan across the base of a plume. It is essential to coordinate with TRACE planners so TRACE 171 A band is observed during the same period of observation. WARNING: None