Study 000323: ACRONYM: Fe9_Offlimb This is a long exposure, large raster intended for measuring the temperature in coronal holes off-limb using the Fe IX 197.86/171.07 ratio. Other diagnostic lines are also obtained (Si VIII, Fe X). TARGET: Off-limb coronal holes EXPOSURE TIME: 100s RASTER: scanning SLIT: 2" STEP SIZE: 2" FOV: 200"x400" DURATION: 3 hours VOLUME: 100 Mbits Pointing: --------- Large, polar coronal hole, off-limb, the slit should be placed from 30” inside the limb to 370” outside the limb Instruction to planners: ----------------------- run following studies: PRY_slot_context_v2 (3min, 4Mbit) Fe9_Offlimb (3 hrs, 100Mbit) PRY_slot_context_v2 (3min, 4Mbit) * No specific support is requested for SOT * XRT should run deep exposures in a wide range of filters to provide temperature measurements. Warning: ------- None