CELIAS MNEMONIC INFORMATION TABLE
The
following table lists the CELIAS mnemonics with specific FOT actions to take in
response to limit violations. The
general rule for mnemonics not listed here is that RED limit violations require
immediate notification to the OE and the experiment representative. YELLOW limit violations require
notification to the OE and the experiment representative only when they are
present (or as soon as they arrive).
An anomaly report is required for any limit violation unless the table below or an Expected Limit Violation sheet specifically directs it is to be ignored.
MNEMONIC |
STATE |
ACTION REQUIRED |
Comments |
FSCP5V, FSCM5V, FSCP13V,
FSCM13V, FSCBUC |
ANY Red or Yellow limit violation
for > 4 consecutive formats. |
Execute Contingency Script
F-02 |
For more info. see Contingency
Script F-02. |
FSDMODM |
Raw Value = 1 |
Notify MTOF representative and
OE. |
Condition will trigger fullhealth configmon
violation. For more info. see OCD# 1276 |
FSMG28C1, FSMVP28C |
ANY Red High or Yellow High limit
violation for > 4 consecutive
formats |
Execute Contingency Script
F-03 |
For more info. see Contingency
Script F-03. |
FSSLVCC, FSSEIT |
ANY Red or Yellow limit violation
for > 4 consecutive formats |
Execute Contingency Script
F-04 |
For more info. see Contingency
Script F-04. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|