LASCO/EIT MNEMONIC
INFORMATION TABLE
The
following table lists the LASCO/EIT mnemonics with specific FOT actions to take
in response to limit violations.
The general rule for mnemonics not listed here is that RED limit
violations require immediate notification to the OE and the experiment
representative. YELLOW limit
violations require notification to the OE and the experiment representative
only when they are present (or as soon as they arrive).
An anomaly report is required for any limit violation unless the table below or an Expected Limit Violation sheet specifically directs it is to be ignored.
MNEMONIC |
STATE |
ACTION REQUIRED |
Comments |
ETE1 |
Red High Limit |
Execute CS L-02 |
For more info. see CS L-02 |
ETE4 |
Red High Limit |
Execute CS L-02 |
For more info. see CS L-02 |
LSESWMOT |
Raw Value = 211 or 212 for >= 450 seconds |
Execute CS L-03 |
Condition will trigger watch
from i_exp_ck.prc. For more info. see OCD# 726 |
L-15AC1 |
Delta Red Limit |
Business hours - Notify
LASCO/EIT representative Non-Business hours - Tell
representative the next day |
For more info. see 08 March
1997 email from C. St. Cyr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|