SUMER MNEMONIC INFORMATION TABLE

 

The following table lists the SUMER mnemonics with specific FOT actions to take in response to limit violations.  The general rule for mnemonics not listed here is that RED limit violations require immediate notification to the OE and the experiment representative.  YELLOW limit violations require notification to the OE and the experiment representative only when they are present (or as soon as they arrive).

 

An anomaly report is required for any limit violation unless the table below or an Expected Limit Violation sheet specifically directs it is to be ignored.

 

MNEMONIC

STATE

ACTION REQUIRED

Comments

Any of the following, where * indicates one or more "any characters":

S+X*

S-X*

SIDET*

SIX*

SSX*

STX*

S+*MC1

STMC1T1

STMC1T2

 

Yellow or Red

 High or Low

Limit violation

for > 8 minutes

 

 

Notify OE & SUMER representative in accordance with Red or Yellow limit rules.

 

Ignore if violation persists for < 8 minutes.

 

 

For more information

see OCD #565,

or OCD #2236.