UVCS MNEMONIC INFORMATION TABLE

 

The following table lists the UVCS mnemonics with specific FOT actions to take in response to limit or configuration monitor violations.  The general rule for mnemonics without specific actions listed here is that ALL UVCS limit violations require immediate notification to the experiment representative.  RED limit violations also require immediate notification to the OE, while YELLOW limit violations require OE notification only when present (or as soon as the OE arrives).

 

An anomaly report is required for any limit violation unless the table below or an Expected Limit Violation sheet specifically directs it is to be ignored.

 

MNEMONIC

STATE

ACTION REQUIRED

Comments

Any UVCS limit not specified below

Yellow or Red High or Low

Notify UVCS representative immediately.  Notify OE immediately if RED, during daytime if YELLOW.

Per OCD# 1306.

UTTHEC1

 

Red High

(in ESR only)

Execute Contingency Script U-02

Per OCD# 1307.

UTTHEC2

 

Red High

(in ESR only)

Execute Contingency Script U-02

Per OCD# 1307.

Any starting with UTTH or UTMT (except UTTHGMBL, UTTHIREU, UTTHTDC) and not otherwise specified below

Yellow or Red High or Low

Execute Contingency Script U-01 if very close in time to a non-contact period of 4 hours or more.

Per ÒUVCS Emergency ActionsÓ email from L. Gardner,

dated 20 Dec 1995

UIPWA

 

Yellow or Red High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWB

 

Yellow or Red High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWM6

Yellow High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWM15

Yellow High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWP5

Yellow High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWP6

Yellow High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWP15

Yellow High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

UIPWP27

Yellow High

Execute Contingency Script U-01

Execute if limit flags > 2 min.

USMD

SAFE

Notify OE & UVCS team immediately.

 

USPWDL

OFF

Notify OE & UVCS team immediately.

 

USPWDO

OFF

Notify OE & UVCS team immediately.

 

USPWDV

ON

Notify OE & UVCS team immediately.

 

USPWHT

OFF

Notify OE & UVCS team immediately.

 

USPWME

OFF

Notify OE & UVCS team immediately.

 

UTMTLAMP

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTLDET

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTLHVP

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTLLVP

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTLMON

Red Low

~ -33 to -38

Degrees C

None

Not an anomaly, per OCD# 398.

 

UTMTLMON

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTLTDC

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTOHVP

Red High

>100 Degrees C

None

Not an anomaly, per OCD# 398.

 

UTMTOHVP

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTOLVP

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTOMON

 

Red Low

~ -33 to -38

Degrees C

None

Not an anomaly, per OCD# 398.

 

UTMTOMON

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTOSCR

 

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)

 

UTMTOTDC

ANY limit

for < 2 mins

None

Not an anomaly (OCD# 1388)