VIRGO MNEMONIC INFORMATION
TABLE
The
following table lists the VIRGO mnemonics with specific FOT actions to take in
response to limit violations. The
general rule for mnemonics not listed here is that RED limit violations require
immediate notification to the OE and the experiment representative. YELLOW limit violations require
notification to the OE and the experiment representative only when they are
present (or as soon as they arrive).
An anomaly report is required for any limit violation unless the table below or an Expected Limit Violation sheet specifically directs it is to be ignored.
MNEMONIC |
STATE |
ACTION REQUIRED |
Comments |
VIPWA |
Violates RH or RL limits for
more than 3 minutes |
Execute CS V-01. |
References: VIRGO EG Part 4. OCD# 1902 |
VIPWB |
Violates RH or RL limits for
more than 3 minutes |
Execute CS V-01. |
References: VIRGO EG Part 4. OCD# 1902 |
VSDAS |
< > hÕxxxFÕ for more
than 3 minutes (where x represents ÒdonÕt
careÓ bits) |
Execute CS V-02. |
Condition will trigger watch
from i_exp_ck.prc. Reference: OCDs# 1383, 1499 |
VT1COMM |
> 70 deg C |
Execute CS V-01. |
Reference: VIRGO EG Part 4. |
VT6COMM |
> 70 deg C |
Execute CS V-01. |
Reference: VIRGO EG Part 4. |
VT8COMM |
> 70 deg C |
Execute CS V-01. |
Reference: VIRGO EG Part 4. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|