VIRGO MNEMONIC INFORMATION TABLE

 

The following table lists the VIRGO mnemonics with specific FOT actions to take in response to limit violations.  The general rule for mnemonics not listed here is that RED limit violations require immediate notification to the OE and the experiment representative.  YELLOW limit violations require notification to the OE and the experiment representative only when they are present (or as soon as they arrive).

 

An anomaly report is required for any limit violation unless the table below or an Expected Limit Violation sheet specifically directs it is to be ignored.

 

MNEMONIC

STATE

ACTION REQUIRED

Comments

 

VIPWA

 

Violates RH or RL limits for more than

3 minutes

 

Execute CS V-01.

 

References:

VIRGO EG Part 4.

OCD# 1902

 

VIPWB

 

Violates RH or RL limits for more than

3 minutes

 

Execute CS V-01.

 

References:

VIRGO EG Part 4.

OCD# 1902

 

VSDAS

< > hÕxxxFÕ for more than 3 minutes

(where x represents ÒdonÕt careÓ bits)

 

Execute CS V-02.

Condition will trigger watch from i_exp_ck.prc.

 

Reference: OCDs# 1383, 1499

VT1COMM

> 70 deg C

Execute CS V-01.

Reference: VIRGO EG Part 4.

VT6COMM

> 70 deg C

Execute CS V-01.

Reference: VIRGO EG Part 4.

VT8COMM

> 70 deg C

Execute CS V-01.

Reference: VIRGO EG Part 4.